· Good high-temperature performance, no need for air conditioning cooling below 40℃, saves energy.
· The PACK module is designed with a modular standard, allowing for flexible combinations and easy maintenance.
· It has a long cycle life, with 3000 cycles at 0.5C/0.5C, 80% DOD, at 25℃.
· The touch LCD provides an intuitive display of various parameters, records, status, and alarms.
· It supports parallel operation of multiple units and cabinet-level fire protection.
· It supports two-line design to meet the requirements of UPS models.
· It features a three-level BMS management system, ensuring the safe and reliable operation of the system from the cell level to the system level.
· It has a high energy density, saving 70% of the floor space compared to lead-acid batteries.
Data center
IT room
| Product model | 5-15mins | |||
| CF24050U | CF48050U | CF486100U | CF512100U | |
| Cell Material | LFP | |||
| Nominal Voltage | 240Vdc | 480Vdc | 486.4Vdc | 512Vdc |
| Rated Charging Voltage | 262.5Vdc | 525Vdc | 532Vdc | 560Vdc |
| Nominal Capacity | 50Ah/12kWh | 50Ah/24kWh | 100Ah/48.64kWh | 100Ah/51.2kWh |
| Self-Discharge Rate | ≤3% (at 0~30°C for 3 months) | |||
| Standard Discharge Current | 50A continuous discharge (1C) | 50A continuous discharge (1C) | 100A continuous discharge (1C) | 100A continuous discharge (1C) |
| Maximum Discharge Current | 300A continuous discharge (6C) | 300A continuous discharge (6C) | 600A continuous discharge (6C) | 600A continuous discharge (6C) |
| Standard Charging Current | 25A(0.5C) | 25A(0.5C) | 50A(0.5C) | 50A(0.5C) |
| Maximum Charging Current | 50A(1C) | 50A(1C) | 100A(1C) | 100A(1C) |
| Cycle Life | 3000 cycles @ 80% DOD, 0.5C/0.5C | |||
| Communication Interface | CAN; RS485; Dry Contact | |||
| Protection Functions | Over-temperature, over-current, short-circuit, over-charge, over-discharge, etc. | |||
| Dimensions(W*D*H) | 600*800*1400mm | 600*800*2000mm | 600*800*2200mm | 600*800*2200mm |
| Certifications | UN | |||
| Environment | ||||
| Storage Temperature | 0~40ºC | |||
| Operating Temperature | 15~45°C (recommended operation at 20~25°C) | |||
| Relative Humidity | 5~95% | |||
| Altitude | ≤2000m | |||
| Cell Specifications | ||||
| Nominal Capacity | 50Ah | |||
| Nominal Voltage | 3.2Vdc | |||
| Operating Voltage Range | 2.5~3.6Vdc | |||
| Battery Module Specifications | ||||
| Configuration | 1P15S | 1P15S | 2P20S/2P18S | 2P20S |
| Nominal Voltage | 48Vdc | 48Vdc | 64/57.6Vdc | 64Vdc |
| Operating Voltage Range | 42~52.5Vdc | 42~52.5Vdc | 56~70Vdc/50.4~63Vdc | 56~70Vdc |
| Battery Cluster Specifications | ||||
| Configuration | 1P75S | 1P150S | 2P152S | 2P160S |
| Nominal Capacity | 50Ah | 50Ah | 100Ah | 100Ah |
| Nominal Voltage | 240Vdc | 480Vdc | 486.4Vdc | 512Vdc |
| Operating Voltage Range | 210~262.5Vdc | 420~525Vdc | 425.6~532Vdc | 448~560Vdc |
| Weight | 290Kg | 430Kg | 790Kg | 810Kg |